-40%

808nm Diode Laser Hair Removal Machine,Freezing,Painless,HR-Black P

$ 2323.19

Availability: 100 in stock
  • Brand: Unbranded
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Condition: New
  • Suitable For: Hair Removal
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • Type: Laser Hair Removal Device
  • Item must be returned within: 14 Days

    Description

    Product Name:
    808 nm Diode Laser Hair Removal Machine,Freezing, Painless
    Price:
    Surprise Price and Amazing Product
    Model No.:
    808-HR-Black P
    (In stock)
    220V or 110V
    Video:
    Keywords:
    808nm Diode Laser  Hair Removal Machine,Freezing, Painless
    Manufacturer:
    OEM ODM (Can design your interface, language translation)
    Contact:
    eBay message or Email
    Advantage:
    Company Advantage:
    1

    We are professional laser diode  manufacture with 10 years experience.
    2

    We are one of the few can  encapsulate a variety of laser chip manufacture.
    3

    We provide OEM & ODM solutions  from laser diodes to full system.
    Product Advantage:
    1

    808nm Laser Hair Removal  Machine is made and designed by ourself,including handpiece, power  control panel, screen and water cooling system.
    2

    808nm laser hair removal has  three main advantage:Freezing,Painless,Permanent hair removal.
    3

    We can change the  interface, the company logo and language according to your  requirements.
    4

    We  are able to provide varieties of interface.
    Specifications:
    Parameter
    Value(Default)
    Note(Customize)
    Wavelength
    808nm+/-10nm
    940nm optional
    Pulse Width
    25ms~400ms
    Repetition Rate
    1Hz~10Hz
    Energy Fluence
    0~120J/cm2
    Up to 150J/cm2 optional
    Beam Type
    Collimated
    Un-collimated optional
    Skin Cooling
    TEC + Sapphire
    < 5℃
    Laser Window
    15x15mm
    Laser Cooling Liquid
    Purified Water
    Tap water allowed
    Cooling Water Volume
    3.0~3.5L
    Handle Piece Flow Rate
    3.5~4.0L/min
    LCD Screen
    8’ Touch LCD
    6’~10.4’ optional
    Pedal Switch
    Support
    Environment Temperature
    5~40℃
    Environment Moisture
    < 80%
    Input VAC
    220VAC / 50-60Hz
    110VAC optional
    Dimension
    ~14x35x19in
    Weight
    ~127lbs
    Installation:
    Do not  power up the system before you checked this manual!
    For  air shipping regulations, the water inside of the machine must be  cleaned. So the user needs to add water the first time when they  receive the machine. Please take following steps to start the hair  removal system.
    1)
    Open  the package. Put the machine and handle piece in the right place for  setup. Open the back panel by releasing the 8 screws with screw  driver. Check following photo and you will find the tube which is  shorted from bottom to the top of the water tank. Release the tube  from the connector. Find a hard tube in the package accessories  (outer diameter 8mm) and connect it to the top connector of the  water tank. Use the plastic funnel to add water into the tank till  the water level is close to 1cm to the top roof of the tank. If the  water tank is not fully filled, there may be [ ERROR 6 ] alarm when  you start the machine. The water can be regular purified water, or  clean tap water without particles >0.1mm diameter. You may need 3~4  liters of water.
    The  water doesn’t need to be changed within at least 6 months if there  is no alarm [ ERROR 6 ]. This alarm is designed with water level  sensor. It means the water is not enough.
    By the  way, do not over-filled the water, or there may be some water  leakage.
    1)
    Install  the back panel with 8 screws.
    2)
    Check  the handle piece if it is in good conditions. And also check the  protection tube of the handle piece. Make sure it is not terribly  bended or pressed. If the tube is terribly bended, this may cause  water jam or not-enough water flow. This is not good for the laser  cooling and may cause problem.
    3)
    Please  confirm if your wall-plug is 200-240VAC. If it is 90-120VAC, please  contact us to switch the voltage.
    4)
    Find  a 10A 220-250V VAC plug wire (you may need an European Model for the  wire), connect to the back panel.
    5)
    Turn  on the air switch at the back panel.
    6)
    Check  if the emergency button is pressed down. If pressed down, please  release it. Or there will be [ ERROR 2 ].
    7)
    Use  the key to start the system and you will enter the blue start page  of the system. After several seconds, you will enter the main  display as follows:
    1)
    When  you enter this software display, you can follow the OPERATION manual  to start the treatment.
    2)
    For  any emergency situation, please press the emergency button (Red  Mushroom) to shut down the laser immediately.
    3)
    After  treatment if you want to turn off the system, you can use the key to  shut it down directly. And turn off the air switch at the back  panel. You can remove the VAC plug if necessary.
    Operation
    Please  check with the LCD display. There are totally 6 parameters to be  set, including: Laser Power, Pulse Width, Repetition Rate, Skin  Cooling Level, Target Energy and Current Energy.
    1)
    The
    Laser  Power
    shows the peak power of the laser. High laser power means  higher pulse energy fluence. For light skin, such as white people  and light color Asian people, laser power can be adjusted higher for  a better performance. Laser Power can be variable from 5%~100%. The  step width is 5%. The typical Laser Power for color II skin is  70%~80%.
    2)
    The
    Pulse  Width
    shows the length of each laser pulse. A longer pulse width  leads to higher pulse energy fluence. Pulse Width can be variable  from 5ms~400ms. The step width is 5ms at <100ms, 10ms at 100-300ms,  50ms at 300~950ms. The most popular pulse width is 50~60ms.
    3)
    The
    Repetition  Rate
    shows the pulses per second of the laser. A higher  repetition rate leads to higher pulse energy fluence. The Repetition  Rate can be variable from 1Hz~20Hz with a step width of 1Hz. For  scanning operation, the most popular repetition rate is 6~15Hz.
    4)
    The
    Fluence
    at  the top-right of the LCD screen shows the laser energy density on  the skin. This energy changes according to the 3 parameters of
    Laser  Power, Pulse Width
    and
    Repetition Rate
    .
    5)
    The
    Skin  Cooling Level
    shows cooling efficiency of the Sapphire Window  and Aluminum Tip of the handle piece. The green block is longer, the  cooling is better. It depends on the feeling of the patents. The  cooling will be switched off if the green block is all removed.  Usually the cooling level is set at 100% level.
    6)
    The
    Treatment  Assistant
    is an energy counter for each treatment. The laser  energy will be counted till the
    Treatment Assistant
    is  ‘RESET’. This is a tool for the treatment to remember how many  Joules have been treated on the patient.
    7)
    The  middle-left of the LCD is the
    Laser Head Life Monitor
    , which  shows how many shots have been done for this handle piece. This is  calculated as 40J per shot, no matter how many pulses. Please  remember this is a standard for warranty.
    8)
    The  bottom-left of the LCD screen shows the system status. There are  totally 5 status.
    A.
    Status:  Setting
    .  This means you are setting parameters. Any interruption to adjust  the parameter during
    Ready
    Status will change the status to ‘
    Setting
    ’.
    B.
    Status:  Ready
    .  When parameters have been set, press READY button on the  bottom-right of the LCD, after 3 seconds, the system will enter ‘
    Ready
    ’  status. In this status, the pump and fans are working and the laser  is ready to use. The skin cooling will also work if already set in  this status.
    C.
    Status:  Working
    .  When the handle piece shots laser pulses, the system will enter to ‘
    Working
    ’  status.
    D.
    Status:  Stand By
    .  When you press ‘Stand By’ button on the bottom-right of the LCD, the  system will enter the ‘
    Stand By
    ’ status. In this status, the  pump and fans will stop. The skin cooling will also stop.
    E.
    Status:  Error 01~04
    This means the system protections take action. You need to check if  anything goes wrong with the system or environment. The error code  is as follows:
    Error#
    Protection
    Possible Reasons
    Error 01
    65°  Temperature Protection
    PCB is too high.
    Error 02
    55° Temperature Protection
    Water temperature >55°C. Please check if the room  temperature is >35°C. The room would better be with air  conditioner. Or it may cause cooling problem for the laser.  If this ERROR happens, you need to move it to a room <35°C.  Re-start the machine and press ready and do not shoot the  laser. The system fan and pump will work for 10 minutes to  cool down the water. After the water is cooled down, the  ERROR should disappear.
    Error 03
    Flow Rate Protection <2L/min
    The water flow for the handle piece is not enough. Check if  you bend the tube too much, or the water connection of the  handle piece is not well-done. Or there is not enough water  in the water tank.
    Error 04
    Water Level Protection
    There is not enough water in water tank.
    9)
    Set  the parameters (Laser Power, Pulse Width, Repetition Rate, Target  Energy / RESET) and press ‘READY’ button to enable the handle piece.  For the typical treatment parameters, you can refer to the  recommended data or experienced doctor’s advice.
    10)
    During  ‘Ready’ status, you can adjust the skin cooling by yourself, or you  can use it at no cooling. You may need to wait for several minutes  before the skin cooling tip becomes cold.
    11)
    Take  the handle piece. Pressure the pedal switch or the switch on the  handle piece to shot the laser pulses. Keep pressing the button and  the laser output will continue.
    Do not press & release for single  pulse.
    12)
    You  can stop the machine anytime by turn off the key in the front panel.
    13)
    Any  sudden situations, press the Emergency Button to stop the laser, and  then turn off the key. The Emergency Button is designed to shut off  the laser, not shut off the VAC. The Key is designed to shut off the  VAC input.
    Packing List:
    Part
    Quantity
    Note
    Laser Machine
    1 SET
    Handle Piece
    1 PC
    Manual
    1 PC
    Not attached for OEM machines
    CE (Electrical Test) Report
    1 PC
    VAC Plug Wire
    1 PC
    Pedal Switch
    1 PC
    Protection Goggles
    2 PCS
    Not attached for OEM machines
    CPC Water Connectors
    Several PCS
    Silicone Soft Tube
    1 PC
    N.W:40KG
    G.W:60KG
    Sales packaging: Export wooden cases
    Packaging size: 63*67*127cm
    Shipping & Handling:
    ·
    The package will  send out within 5 days after  payment.
    ·
    ·
    The shipment usually  takes 5~7 workdays.
    ·
    ·
    Shipment:DHL/TNT/UPS/Fedex/EMS
    ·
    ·
    Payment:
    You can pay 30%  deposit for advance. The product will be arranged right after we  receive the deposit, then we will send you a photo to confirm.If no more questions, pay  off the residual balance and we will send out the product.
    Warranty:
    Please take necessary protections  for the operation of the machine and  handle piece, and notice that  following situations can not be  warranted:
    1)
    Operation  the system without water.
    2)
    Power  up the system without connecting the  handle piece.
    3)
    Regular  drops of the handle piece.
    4)
    Wrong  input VAC.
    Other manual operating  mistakes.
    Warranty

    13  months or 6 million times
    .
    First come, first to take.
    We provide life-long technical  service.
    Applications:
    Hair Removal
    Maintenance:
    1.
    T     1.The water must be  checked and changed every 6 months.
    2)
    2.
    The machine must be  operated in a room with  air-conditioner. The room  temperature is better <28°C.
    3)
    3.
    The environment temperature  can not go below ZERO, or the ice  may damage the water tanks and water  channels
    inside  the machine and the handle piece.
    4)
    4.
    Clear the gel on the handle  piece and make sure there is no dust  attached on the handle piece window.
    5)
    5.
    Do not bend the tube of the  handle piece too hard, or this may  cause flow switch ERROR.
    6)
    6.
    Do not plug in & out the  handle piece connectors frequently.  This may cause bad connections and  may cause
    water  leakage or not well electrical  connections.
    7.Do not shot the laser at random  targets, or it may cause burning or  fire.
    If  you have this demand, please contact me as soon as possible!
    WE CAN PROVIDE QUICK RESPONSE ABOUT YOUR AFTER-SALES PROBLEM.