BR200 GENERATOR INTERLOCK KIT FOR EATON / CUTLER HAMMER / CHALLENGER 150 200 BR

$ 21.11

Availability: 87 in stock
  • Brand: Unbranded
  • Mounting Style: Bolt-On
  • Country/Region of Manufacture: United States
  • Material: Plastic
  • Condition: New

    Description

    For sale is a
    BRAND NEW
    BR200 GENERATOR INTERLOCK KIT FOR EATON / CUTLER HAMMER or CHALLENGER 150 & 200 Amp BR.
    This BR200 Interlock Kit fits Eaton/ Cutler Hammer BR Series, BR Series with plug-on neutral, and CH Series with plug-on neutral, both 150 & 200 amp panels that have a horizontal throw single main breaker with 1-1/4 " to 1-1/2" spacing between the closest edge of the main breaker cut-out and the closest edge of the generator breaker panel cut-out. This generator interlock is compatible with main breakers at the top or bottom of the panel, but in the installation pictures below the main breaker is at the top.
    This kits includes
    :
    1 x 2-piece 3D printed generator breaker interlock assembly with mounting screws
    1 x high quality 3/16" drill bit
    2 x generator backfeed breaker retaining straps (zip ties)
    Breakers & panel box are
    not
    included
    Installation Instructions
    :
    1. Generator backfeed breakers must occupy the top 2 right positions if your main breaker is at the top of your panel, or the lower 2 left positions if your main breaker is at the bottom of your panel.
    2. Observe how the screws are assembled into the interlock because these will be reinstalled the same way in step #5. Disassemble the interlock (unscrew the 3 screws) and place the bottom plate (the black piece with 3 holes in it) below the bottom right breakers (if your main breaker is located at the bottom of the panel) or above the top left breakers (if your main breaker is located at the top of the panel). Note that it should wrap around the raised main cutout as shown:
    3. Using the bottom plate as a template, mark the 3 hole locations. Carefully remove the breaker cover from the breaker panel and drill the 3 holes using the included 3/16" drill bit:
    4. Insert the 3 included screws through the back of the panel cover and mount the bottom & top plates of the interlock as shown. The male side of the screws should be inserted through the back of the cover into the bottom plate. The female receiver side of the screws should be mounted on the front of the panel through the top interlock plate labelled "Generator Interlock." Torque the screws snug but loose enough that the top interlock plate can slide against the bottom plate to operate the interlock:
    5. Turn the main breaker to the "OFF" position for safety. Using the 2 supplied zip ties, secure the 2 generator backfeed breakers to the 2 opposite breakers. Tighten the zip ties and trim the excess. (Note: "Do Not Remove" label in picture below is
    not
    included.)
    6. Reinstall the panel cover and test the interlock to ensure that it prevents the generator backfeed breakers and the main breaker from both being in the "ON" position at the same time. Here you see that the generator backfeed breakers are "OFF" while the main breaker is "ON." The generator backfeed breakers cannot be switched to "ON" without first turning the main breaker to "OFF" and sliding the top piece of the interlock.
    7. (OPTIONAL STEP): Install labels to indicate that generator backfeed breakers are installed. Labels are
    not
    included.
    Please note that if the panel cover is removed, the generator breaker is
    never
    to be turned to the "ON" position. Any electrical equipment should be installed and maintained by qualified personnel. Buyer assumes responsibility for any consequences of improper installation or use.